Utility drawer features fully welded construction of 16-gauge steel. The drawer mounts to front rack rails using standard EIA spacing and feature ball-bearing slides for smooth operation.
Primary voltage shall be 70V with a power rating of 100watts
Primary taps shall be available at 100, 64, 32, 16 watts
Secondary impedance taps shall be available at 8-ohms and 4-ohms
All taps shall have color-coded and clearly marked leads
Frequency response of the transformer shall be with insertion loss not to exceed 0.6dB