The RC-74DL is a 12-button master room controller with a digital volume knob for multimedia rooms. The unit can function either as a standalone controller or as part of a more complex room control system to control audio components, video components and other room facilities such as lights and screens.
Macro Capability-Carries out multiple commands with a single press of a button.
Command Banks-Each button offers multiple layers of functions for alternate behavior, toggle functionality, and more.
1 USB Port-For programming.
3 Bidirectional RS-232 Ports-Control AV equipment such as projectors, LCD and PDP displays, power amplifiers, switchers and scalers.
2 IR Outputs-Additional control port for AV equipment.
IR Learning Function-Learns commands from IR remotes.
4 Contact Closure Ports-Conveniently control other room items related to the AV system such as raising and lowering drapes, the screen or the projector.
2 GPI/O Ports-General purpose I/O ports that can be configured by K-Config as digital inputs, digital outputs or analog inputs for interfacing with a variety of devices such as sensors, switches, LEDs, or relays.
2 K-NETâ„¢ Connectors-Connect to other control panels or a central control processor.
K-NETâ„¢ Control Channel-Provides power and control data to the wall plate controllers over a single cable.
Kramer Site-CTRL Compatible-For network remote control and management using Kramer Site-CTRL software over the Ethernet port.
Configured with Kramer K-Config Software.
Mud Ring Supplied for Easy Installation.
Size-Wall Plate - 3 gang US.
Applications
Multimedia
Classrooms
Auditoriums
Conference rooms
Distributed Signal Types - Audio
Distributed Signal Types - Video
Warranty - Yes
Spec Sheet available - Yes
Number of Inputs:
10
Number of Outputs:
6
Current Draw:
0.57 Amps
DC Voltage:
12 Volts
Shipping Depth (with packaging):
212.09 mm
Shipping Height (with packaging):
71.88 mm
Shipping Width (with packaging):
351.03 mm
Shipping Weight:
0.70 kg
Warranty (Length/Type):
7 Years Limited
PORTS::
3 RS-232, 1 RS-485, 2 GPI/O and 2 K-NET on terminal block connectors; Ethernet on an RJ-45 connector; 1 infrared sensor, 1 USB for programming.
OUTPUTS::
2 IR, 4 relays (36V AC or DC, 2A, 60V AC maximum on non-inductive load).
DEFAULT IP SETTINGS::